What is the difference between a diesel generator and a gasoline generator?

What is the difference between a diesel generator and a gasoline generator?

The first difference between diesel generators and gasoline generators is the difference in fuel oil. The fuel for diesel generator sets is diesel, and the fuel for gasoline generator sets is gasoline.
Second, the ignition method. In the cylinder of a gasoline engine, the mixture of fuel and air is ignited by a spark plug. In a diesel engine, the mixture is ignited by the heat generated by compression.
Then the fuel and air are mixed. In a gasoline engine, fuel and air are mixed in the carburetor and intake pipe. In a diesel engine, the mixing of fuel and air occurs after the diesel is drawn into the cylinder.
Fourth, the output power of diesel generator sets is far greater than that of gasoline generator sets. Generally, the maximum power of gasoline generator set is only 10KW, while the minimum power of diesel generator set is 8KW, and the maximum power can reach 2000KW.
Fifth, gasoline generator sets are small in size and easy to move, while diesel generator sets are large in size and inconvenient to move.
The sixth type has a different range of use. Gasoline generators have low power, generally about 5KW, and can be used for general household lighting and air conditioning; diesel generators are commonly used power generation equipment in enterprises and factories.
After knowing the difference between the two, how to choose the right diesel generator?
When purchasing diesel generators, customers are often confused about which diesel generator to choose. Indeed, when buying diesel generators, the power selection of diesel generators is very important. If it is too large, it will increase the cost; if it is too small, it will not be able to meet the electricity demand.
First you need to choose the right power supply:
Commonly used electrical appliances: such as computers, TVs, electric lights, floodlights, etc., according to the rated power plus = total power consumption;
Electric heating appliances: microwave ovens, water heaters, water heaters, induction cookers, etc. The power of these appliances is calculated to be 1.5 to 2 times the total power consumption.
Induction equipment: air conditioners, water pumps, refrigerators, air compressors, motors, etc. The power calculation method is 2.5-3 times the rated power = total power consumption.
Note: Diesel generator power is usually selected according to the number of electrical equipment and total power. The power of the generator not only increases the power of all electrical equipment, but also increases the way the electrical equipment starts. Generally speaking, the start mode is divided into direct start and step-down start or soft start. Therefore, when selecting the power of a generator set, in addition to the sum of all electrical appliances, the starting power of each electrical appliance must also be considered.
Also, customers need to avoid three misunderstandings:
Confusing the relationship between KVA and KW, treating KVA as an exaggerated KW power and selling it to customers. In fact, KVA is the apparent power, and KW is the effective power. The relationship between them is 1KVA=0.8KW. Import units are usually expressed in KVA, while household appliances are usually expressed in KW. Therefore, when calculating the power, KVA should be converted to KW and multiplied by 0.8.
Confusing the relationship between rated power and maximum power, simply say “power”, and then sell the maximum power as rated power to customers. In fact, maximum power = 1.1x rated power. In addition, within 12 hours of continuous operation, the maximum power can only be used for 1 hour.
In order to reduce costs, the power of the diesel generator is the same as that of the generator. In practice, the industry generally stipulates that the power of diesel generators is greater than or equal to 10% of the generator power due to mechanical losses. To make matters worse, some people mistakenly report the horsepower of diesel generators to users in kilowatts, and configure the unit (usually called small trams) as smaller diesel generators, thereby reducing the service life of the unit, Frequent maintenance and high usage costs.
As an important part of diesel generators, what is the combustion process of diesel engines?
The combustion process of diesel generators is generally divided into four stages: ignition delay stage, rapid combustion stage, slow combustion stage and post-combustion stage.
Ignition delay refers to a series of physical and chemical preparation processes from fuel injection to ignition, including spraying, heating and evaporation, diffusion, mixing, and initial oxidation. It is an important parameter in the combustion process and directly affects the characteristics of the combustion heat release process.
The fuel injected into the combustion chamber during the ignition delay period burns almost simultaneously during the rapid combustion period, so the heat release rate is very high, and the pressure rises very quickly.
In the retarding phase, the fuel combustion depends on the mixing rate. Therefore, strengthening the air turbulence in the combustion chamber and accelerating the mixing of air and fuel play an important role in ensuring that the fuel is quickly and completely burned near the top dead center.
The mixing and burning time of a diesel engine is relatively short, part of the fuel cannot be burned in time near the top dead center, and the heat released at the end of the expansion stroke cannot be fully utilized. Therefore, it is necessary to avoid the fuel burning in the post-combustion stage.
How to extend the service life of a diesel generator?
The life of a generator set depends on how it is used correctly at ordinary times. If it is maintained in accordance with the technology used, it will directly increase its service life. To make it clear, first, the air filter of the generator set contains the wearing parts, the oil filter and the diesel filter, which prolong the service life of the diesel generator set. During the use process, the air filter will be strengthened. Oil filter and diesel filter are maintained and fully play their role.
When installing, the air filter must not leak, reverse or install the sealing gasket and rubber connecting pipe by mistake, and ensure the sealing of each embedded part. The paper dust cup air filter is cleaned every 50-100 hours. The dust on the surface can be brushed off with a soft brush. If it is used for more than 500 hours or damaged, it should be replaced in time. Use oil bath air filter, clean the filter element with clean diesel every 100-200 hours, and replace the oil in the filter element. If the filter element is broken, replace it immediately, and pay attention to refueling according to regulations during use.
If the oil filter is not maintained in time during the operation of the diesel generator, the filter element will be blocked, the pressure of the oil will increase, the safety valve will open, and the lubricating oil will flow directly into the main oil passage, which will increase the wear and tear of the lubricated surface. Affect the service life of diesel generators. Therefore, the oil filter should be cleaned every 180-200 hours. If damage is found, it should be replaced immediately to prevent impurities from entering the lubricated surface.
When the generator set is used in different seasons, the crankcase and all lubricated surfaces should be cleaned. The method is to use motor oil, kerosene, and diesel as washing oil. Wash oil can be added to wash after draining the oil.
All types of fuel filters in the fuel supply system are cleaned every 100-200 hours, and the fuel tank and all oil pipelines must be thoroughly cleaned. When cleaning the filter element and seals, you should be especially careful, if any damage is found, it needs to be replaced in time. During seasonal oil changes, all parts of the entire oil supply system should be cleaned. The diesel used should meet the seasonal requirements and undergo a 48-hour precipitation purification treatment.
When choosing a diesel generator set, the main considerations include electromechanical performance, usage of the diesel generator set, load capacity and variation range, operating environmental conditions (including altitude, climate conditions, noise), and automation functions of the diesel generator set. Since diesel generator sets can be used in general, standby and emergency situations, different uses have different requirements for diesel generator sets.
How to choose ordinary diesel generator set?
Ordinary units have long working hours and large changes in load curves. Unit capacity, unit number, unit type, unit control method are different from emergency unit.
How to choose a spare diesel generator set?
When the calculated carrying capacity multiplied by the demand factor is less than the capacity of the emergency diesel generator set, the reserve factor should be considered as 1.2, that is, the 1.2 times calculated capacity is less than the capacity of the emergency diesel generator set. After a power failure, the emergency generator set should supply power to the load . If the calculated load multiplied by the demand factor is greater than the capacity of a single emergency diesel generator set, two automatic generator sets with the same model, capacity, voltage regulation, and speed regulation characteristics can be selected. One or two power supply devices for household and commercial use; when there is a power outage and a fire occurs, two units will supply power to the fire load for fire treatment.
How to choose emergency diesel generator?
Emergency diesel generator sets should generally be high-speed, pressurized, low fuel consumption diesel generator sets with the same capacity. The high-speed supercharged diesel engine has large capacity and small space occupation. The diesel engine is equipped with electronic or hydraulic speed control device, which has good speed control performance. The generator should be a synchronous motor with brushless excitation or phase composite excitation device, which is more reliable, has low failure rate and is easy to maintain. When a single air conditioner or motor has a large capacity in the first load, the third harmonic excitation generator should be selected.
Selection of unit start mode. There are three starting methods for diesel engines: (1) manual start; (2) electric start; compressed air start. High-rise buildings should adopt electric starting mode, avoid using compressed air starting mode. In a type of high-rise buildings, diesel generators with self-starting devices must be selected. Once the power supply to the city network is interrupted, it must be supplied within 15 seconds (30 seconds required by the high meter). In second-level high-rise buildings, when conditions permit, units with self-starting devices can also be used. When difficulties arise, a manual activation device can also be used.
What are the causes and hazards of oil leakage of silent diesel generators?
Once the silent diesel generator leaks, it must be repaired in time, otherwise it will not only damage the equipment, but also cause danger. What is the reason for the silent failure of the generator? There are many sealing methods for mechanical equipment, such as cylinder liners, piston rings, and superchargers. This kind of seal generally plays a full role when the initiator load is about 1≤3. When the load is small, a slight leakage may occur. The causes and hazards of oil leakage of silent diesel generators are as follows:
The piston and cylinder liner of the silent diesel generator are poorly sealed, causing the fuel to rise and burn;
Due to factors such as low load, no load, low turbocharging pressure, etc., the sealing effect of the equipment will also be affected, causing spilled oil to enter the cylinder;
Part of the oil flow is burned through the cylinder, and the rest is unburned. This part will form carbon deposits, which are discharged with the exhaust gas. When the exhaust pipe of the silent generator is assembled or carbon deposits are formed, when oil and carbon accumulate to a certain extent, it will flow out from the interface of the exhaust manifold.
The accumulation of oil in the compressor of the silent diesel generator to a certain position will also cause leakage of the supercharger joint surface;
The silent power generation time is long, and the small load operation will cause the mechanical equipment parts to be broken and cause incineration, so it must be handled and repaired in time. Low load and no-load operation time should be minimized.